1.
Crit Care Explor ; 2(5): e0118, 2020 May.
Article in English | MEDLINE | ID: covidwho-1791048

ABSTRACT

OBJECTIVES: To design and test a ventilator circuit that can be used for ventilation of two or more patients with a single ventilator, while allowing individualization of tidal volume, fractional concentration of oxygen, and positive end-expiratory pressure to each patient, irrespective of the other patient's respiratory system mechanics. DESIGN: Description and proof of concept studies. SETTINGS: Respiratory therapy laboratory. SUBJECTS: Ventilation of mechanical test lungs. INTERVENTIONS: Following a previously advocated design, we used components readily available in our hospital to assemble two "bag-in-a-box" breathing circuits. Each patient circuit consisted of a flexible bag in a rigid container connected via one-way valve to a test lung, along with an inline positive end-expiratory pressure valve, connected to the ventilator's expiratory limb. Compressed gas fills the bags during "patient" exhalation. During inspiration, gas from the ventilator, in pressure control mode, enters the containers and displaces gas from the bags to the test lungs. We varied tidal volume, "respiratory system" compliance, and positive end-expiratory pressure in one lung and observed the effect on the tidal volume of the other. MEASUREMENTS AND MAIN RESULTS: We were able to obtain different tidal volume, dynamic driving pressure, and positive end-expiratory pressure in the two lungs under widely different compliances in both lungs. Complete obstruction, or disconnection at the circuit connection to one test lung, had minimal effect (< 5% on average) on the ventilation to the co-ventilated lung. CONCLUSIONS: A secondary circuit "bag-in-the-box" system enables individualized ventilation of two lungs overcoming many of the concerns of ventilating more than one patient with a single ventilator.

2.
HardwareX ; 11: e00260, 2022 Apr.
Article in English | MEDLINE | ID: covidwho-1611945

ABSTRACT

Development of emergency use ventilators has attracted significant attention and resources during the COVID-19 pandemic. To facilitate mass collaboration and accelerate progress, many groups have adopted open-source development models, inspired by the long history of open-source development in software. According to the Open-source Hardware Association (OSHWA), Open-source Hardware (OSH) is a term for tangible artifacts - machines, devices, or other physical things - whose design has been released to the public in such a way that anyone can make, modify, and use them. One major obstacle to translating the growing body of work on open-source ventilators into clinical practice is compliance with regulations and conformance with mandated technical standards for effective performance and device safety. This is exacerbated by the inherent complexity of the regulatory process, which is tailored to traditional centralized development models, as well as the rapid changes and alternative pathways that have emerged during the pandemic. As a step in addressing this challenge, this paper provides developers, evaluators, and potential users of emergency ventilators with the first iteration of a pragmatic, open-source assessment framework that incorporates existing regulatory guidelines from Australia, Canada, UK and USA. We also provide an example evaluation for one open-source emergency ventilator design. The evaluation process has been divided into three levels: 1. Adequacy of open-source project documentation; 2. Clinical performance requirements, and 3. Conformance with technical standards.

3.
PLoS One ; 16(3): e0247575, 2021.
Article in English | MEDLINE | ID: covidwho-1573727

ABSTRACT

INTRODUCTION: The COVID-19 pandemic has led to widespread shortages of N95 respirators and other personal protective equipment (PPE). An effective, reusable, locally-manufactured respirator can mitigate this problem. We describe the development, manufacture, and preliminary testing of an open-hardware-licensed device, the "simple silicone mask" (SSM). METHODS: A multidisciplinary team developed a reusable silicone half facepiece respirator over 9 prototype iterations. The manufacturing process consisted of 3D printing and silicone casting. Prototypes were assessed for comfort and breathability. Filtration was assessed by user seal checks and quantitative fit-testing according to CSA Z94.4-18. RESULTS: The respirator originally included a cartridge for holding filter material; this was modified to connect to standard heat-moisture exchange (HME) filters (N95 or greater) after the cartridge showed poor filtration performance due to flow acceleration around the filter edges, which was exacerbated by high filter resistance. All 8 HME-based iterations provided an adequate seal by user seal checks and achieved a pass rate of 87.5% (N = 8) on quantitative testing, with all failures occurring in the first iteration. The overall median fit-factor was 1662 (100 = pass). Estimated unit cost for a production run of 1000 using distributed manufacturing techniques is CAD $15 in materials and 20 minutes of labor. CONCLUSION: Small-scale manufacturing of an effective, reusable N95 respirator during a pandemic is feasible and cost-effective. Required quantities of reusables are more predictable and less vulnerable to supply chain disruption than disposables. With further evaluation, such devices may be an alternative to disposable respirators during public health emergencies. The respirator described above is an investigational device and requires further evaluation and regulatory requirements before clinical deployment. The authors and affiliates do not endorse the use of this device at present.


Subject(s)
COVID-19/prevention & control , Equipment Design/instrumentation , Filtration/instrumentation , Pandemics/prevention & control , Personal Protective Equipment , Respiratory Protective Devices , Ventilators, Mechanical , Equipment Reuse , Face , Humans , Materials Testing/instrumentation , N95 Respirators , Occupational Exposure/prevention & control , Printing, Three-Dimensional/instrumentation , SARS-CoV-2/pathogenicity
4.
PLoS One ; 15(11): e0242304, 2020.
Article in English | MEDLINE | ID: covidwho-926880

ABSTRACT

INTRODUCTION: The COVID-19 pandemic has unveiled widespread shortages of personal protective equipment including N95 respirators. Several centers are developing reusable stop-gap respirators as alternatives to disposable N95 respirators during public health emergencies, using techniques such as 3D-printing, silicone moulding and plastic extrusion. Effective sealing of the mask, combined with respiratory filters should achieve 95% or greater filtration of particles less than 1um. Quantitative fit-testing (QNFT) data from these stop-gap devices has not been published to date. Our team developed one such device, the "SSM", and evaluated it using QNFT. METHODS: Device prototypes were iteratively evaluated for comfort, breathability and communication, by team members wearing them for 15-30min. The fit and seal were assessed by positive and negative pressure user seal checks. The final design was then formally tested by QNFT, according to CSA standard Z94.4-18 in 40 volunteer healthcare providers. An overall fit-factor >100 is the passing threshold. Volunteers were also tested by QNFT on disposable N95 masks which had passed qualitative fit testing (QLFT) by institutional Occupational Health and Safety Department. RESULTS: The SSM scored 3.5/5 and 4/5 for comfort and breathability. The median overall harmonic mean fit-factors of disposable N95 and SSM were 137.9 and 6316.7 respectively. SSM scored significantly higher than disposable respirators in fit-test runs and overall fit-factors (p <0.0001). Overall passing rates in disposable and SSM respirators on QNFT were 65% and 100%. During dynamic runs, passing rates in disposable and SSM respirators were 68.1% and 99.4%; harmonic means were 73.7 and 1643. CONCLUSIONS: We present the design and validation of a reusable N95 stop-gap filtering facepiece respirator that can match existent commercial respirators. This sets a precedence for adoption of novel stop-gap N95 respirators in emergency situations.


Subject(s)
Coronavirus Infections/prevention & control , Equipment Design , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Respiratory Protective Devices/standards , Adult , Betacoronavirus , COVID-19 , Equipment Failure Analysis , Equipment Reuse , Female , Filtration , Humans , Male , Middle Aged , SARS-CoV-2